À¯¼öºÐ¸®ÀåÄ¡(Auto Water Drain System)

  ¾÷ü¸í

:

ûÇØ¿£Áö´Ï¾î¸µ    TEL  : 062-525-1570
  »óÇ°¼³¸í : ¡á -À¯/°ø¾Ð ±â±âÀÇ À¯·ù ¹× °ø±âÀúÀå ÅÊÅ©ÀÇ ¼öºÐÀ» ÀÚµ¿À¸·Î ºÐ¸®/¹èÃâ ½ÃÅ°´Â ÀåÄ¡·Î¼­ ½Ç¿ë½Å¾Èµî·Ï Á¦0258212È£ Á¦Ç°ÀÓ. (*»ç¿ëÀÚ Áß½ÉÀ¸·Î °³¹ßµÈ ÀåÄ¡À̹ǷΠ»ç¿ëÀÚ°¡ ¿øÇÏ´Â ´Ù¾çÇÑ ¸ð¾ç°ú ±â´ÉÀ» Ãß°¡,»èÁ¦ÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù.)

- À¯·ù ¹× °ø±âÀúÀå ÅÊÅ©ÀÇ ¹èÃⱸ¿¡ º¸Á¶ÅÊÅ©¸¦ ÀåÂøÇÏ¿© º» ÅÊÅ©ÀÇ
À¯·ù³ª ¾Ð·Â ¼Õ½Ç ¾øÀÌ ¿ÜºÎ ¶óÀο¡¼­ À¯ÀÔµÈ ¹°À̳ª ½ºÄÉÀÏ µîÀÇ À̹°Áú°ú ÅÊÅ© ³»ºÎ¿¡¼­
ÀÚüÀûÀ¸·Î ¹ß»ýÇÏ´Â ÀÀÃà¼ö ¸¸À» ÀÚµ¿À¸·Î ºÐ¸®¹èÃâ ½ÃÅ°´Â ÀåÄ¡ÀÔ´Ï´Ù.

- ±¸¼º : 1) ¼¾¼­ºÎ : ¼¼°³ÀÇ ¼¾¼­ºÀÀ¸·Î ±¸¼ºµÇ¸ç,DC5V°¡ °ø±ÞµÇ¾î ¼öºÐ ÇÔÀ¯ »óÅ¿¡ µû¶ó 0¿¡¼­255±îÁö CONTORRERÀÇ LCDâ¿¡ Ç¥½ÃÇÏ¿© ÇÔÀ¯¼öºÐÀÇ »óŸ¦ ³ªÅ¸³¿.

 2) ÄÁÆ®·Ñ·¯ : ÀԷºÎ,Ãâ·ÂºÎ·Î ±¸¼ºµÇ¸ç ¸¶ÀÌÅ©·ÎĨ»çÀÇ PIC16C7X°èÀÇ ¿ø Ĩ ¸¶ÀÌÄÄÀ» »ç¿ëÇÏ°í ROM,RAM,TIMER,I/O PORT(8°³ ¾Æ³ª·Î±× ÀÔ·ÂÆ÷Æ®.16°³ÀÇ µðÁöÅÐ ÀÓÃâ·Â Æ÷Æ®),A/D,PWM,RS232C µîÀÇ ±â´ÉÀ» ÇϳªÀÇ Ä¨¿¡ ¸ðµÎ °®Ãß°í ÀÖÀ¸¸ç ¼¾¼­ºÎ¿¡¼­ ÀÔ·ÂµÈ ½ÅÈ£·Î ÆÇ´ÜÇÏ¿© ¹°À» ÀÚµ¿À¸·Î ¹èÃâÇÏ´Â ¿ªÇÒÀ» ¼öÇàÇÑ´Ù, 

3) º¸Á¶ÅÊÅ© : ÁÖÅÊÅ© ÇϺο¡ ÀÖ´Â ¹èÃâ¹ëºê¿Í ¹è°üÀ¸·Î ¿¬°áµÇ¾î À¯ÀԵǴ ¹°°ú ±â¸§ÀÇ È¥ÇÕ¹°À» ÀÚ¿¬ºÐ¸®ÇÏ¿© ¹°Àº ÀÚµ¿À¸·Î ¹èÃâÇÏ°í ±â¸§Àº ÁÖÅÊÅ©·Î ´Ù½Ã º¸³»ÁÖ´Â ±â´É.

- »ç¿ë°³¼Ò : ±¤¾çÁ¦Ã¶¼Ò, Æ÷Ç×Á¦Ã¶¼Ò, â¿øƯ¼ö°­µî °øÀå¿¡¼­ »ç¿ëµÇ°í ÀÖÀ¸¸ç, Á¤À¯°øÀåµî À¯·ùÀúÀåÅÊÅ©¸¦ º¸À¯ÇÑ °÷¿¡¼­´Â ¾î´À°÷¿¡³ª È°¿ë°¡´ÉÇϸç, ¿À¿°¹æÁö ¼³ºñ¿ëÀ¸·Îµµ »ç¿ë°¡´É.

*. Oil/Water Separation and Auto Water  Drain System

Oil/Water Separation and auto Water  drain System(call "system" in follow) is operated by Sub tank which is connected to main oil tank through drain pipe, controller which check the water/oil condition and open/close valve according to the oil/water condition in sub tank, sensor that distinguish water from oil.

1.Controller

  1) Keypad: Control the value (0 to 255) to open or close the valve.    Approaching to 0 means oil and approaching to 255 will mean water.

  2) LCD window: display current value of the condition of oil/water.

  3) Selector Switch: Auto/manual selecting switch. If switch is set to auto, system will be controlled by automation.

  4) Led lamp: light red when valve opened.

  5) Main switch: Be at the bottom of the controller.

2. Sub Tank

   Main system where separate water from oil and return oil to main tank, drain water, Connected to main tank through pipe. Pump is located on top of tank.

3. Sensor

   Sensor the condition of the oil/water and classify it to 0  255 according to quantity oil in water.